X3T9.2/89-102 August 7, 1989 Mr. John Lohmeyer Chairman X3T9.2 NCR MS21 3718 N. Rock Road Wichita KN 67226 Dear John, Tom Wicklund brought to my attention a boo-boo in the documentation of Synchronized Spindles in the ESDI document. At present Table 30 (in 7.18.4) and Section K.3 (Annex K) reflect the following for the bit settings of setting synchronization mode: | | 1 1 0 0 | Set Synchronized Drive | | | | x'00' = Slave | | | | x'01' = Master | | | | x'11' = Master Control | | | | x'80' = Unsynchronize | The Master Control is incorrect - it should have been x'03'. All other values in the table are binary, so I have modified the master documents as follows to correct the error. | | 1 1 0 0 | Set Synchronized Drive | | | | 0000 0000 = Slave | | | | 0000 0001 = Master | | | | 0000 0011 = Master Control | | | | 1000 0000 = Unsynchronize | We should let the membership know of this, as it is possible that some companies implemented to the intent, and others to the error. Yours sincerely, I. Dal Allan