A big thank you to all who responded! I was just wondering if anyone
may know where I can reference the situations which cause an implicit
LOGO/PRLO, or maybe is this a better question to ask T11? FC-LS-2
section 6.4.4 seems to be vague on the issue, and doesn't mention this
case.
Thanks,
--
Shawn Authement
Sr. Software Engineer
Texas Memory Systems, Inc.
Shawn.Authement@texmemsys.com
ph: +1.713.266.3200
Kevin D Butt wrote:
Shawn,
Yes, when an N_Port performs a
PLOGI/PRLI
it logs in again. This can be viewed as an implicit LOGO/PRLO and
as stated in 4.11 of FCP-4 (http://www.t10.org/ftp/t10/drafts/fcp4/fcp4r01.pdf)
this generates an I_T nexus loss notification.
Regards,
Kevin D. Butt
SCSI & Fibre Channel Architect, Tape Firmware
MS 6TYA, 9000 S. Rita Rd., Tucson, AZ 85744
Tel: 520-799-2869 / 520-799-5280
Fax: 520-799-2723 (T/L:321)
Email address: kdbutt@us.ibm.com
http://www-03.ibm.com/servers/storage/
* From the T10 Reflector (t10@t10.org), posted by:
* Shawn Authement <Shawn.Authement@texmemsys.com>
*
All,
I am currently researching device behavior with respect to N_Port login
and was wondering if anyone can provide clarification.
Q: If an already-logged-in N_Port performs login again (via PLOGI), is
this considered an I_T nexus loss as defined by SAM-3, 6.3.4?
The ENDL Fibre Channel Bench Reference implies that re-Login causes an
implicit Logout. However, I cannot find any supporting information
in
either the FCP-3 for FC-LS specifications. My goal is to ultimately
determine whether a SCSI Target Port should set a Unit Attention if a
SCSI Initiator Port re-logs in.
Thank you for your your help!
--
Shawn Authement
Sr. Software Engineer
Texas Memory Systems, Inc.
Shawn.Authement@texmemsys.com
ph: +1.713.266.3200
*
* For T10 Reflector information, send a message with
* 'info t10' (no quotes) in the message body to majordomo@t10.org