From: Halvard Eriksen <Halvard.Eriksen@tandbergstorage.com>
To: "t10@t10.org" <t10@t10.org>
Date: Wed, 17 Sep 2008 09:30:59 +0200
Subject: SSC-3, Response to Letter Ballot comment  IBM-38
X-Message-Number: 9099
Formatted message: HTML-formatted message
Attachment #1: image001.gif
Attachment #2: image002.png

To the SSC working group.
Tandberg Storage is currently not using TapeAlert flag 21.
We would however prefer that TapeAlert flag 21 stays active
until cleared by a Log Sense or until a new cartridge is inserted
and/or loaded. In a system that polls Tape Alert it is easy to
miss this flag if it is set when the Eject Button is set and cleared
when the cartridge has been ejected.
Halvard Eriksen
Senior Engineer
halvard.eriksen@tandbergstorage.com<mailto:lasse.skallerud@tandbergstorage.co
m>
[cid:image002.png@01C918A6.671336C0]
PHILIP PEDERSENS VEI 1,
1366 LYSAKER.
Front Desk: 23706000
Direct Line: 23706031