Subject: SAS 2 - Inconsistency between SP state machine and Table 272 Date: Thu, 17 Apr 2008 10:25:50 -0600 From: "Day, Brian" <Brian.Day@lsi.com> To: <t10@t10.org> X-Message-Number: 8726 Formatted message: HTML-formatted message In r14 spec, there is the following: 6.8.3.3.3 Transition SP1:OOB_AwaitCOMX to SP4:OOB_COMSAS This transition shall occur after receiving either a COMINIT Detected message or a COMSAS Detected message. If COMSAS Detected was received, this transition shall include a COMSAS Detected argument. If the ATTACHED SATA PORT SELECTOR bit is set to one in the SMP DISCOVER response (see 10.4.3.10), the state machine shall, before the transition: a) set the ATTACHED SATA PORT SELECTOR bit to zero in the SMP DISCOVER response; and b) send a SATA Port Selector Change confirmation to the link layer. So when connected to the active port of a port selector, after receiving the COMINIT from the SATA target, the ATTACHED SATA PORT SELECTOR bit is cleared. However, Table 272 indicates that the active port of port selector should still have this bit asserted. I think should be discussed during letter ballot comment resolution. Early comments? __________ Brian Day LSI Corp. (719) 533-7468