To: t10@t10.org Subject: SMC-3: IBM Action Item 14Jan08-01 (setting of 6/2800) From: Kevin D Butt <kdbutt@us.ibm.com> Date: Tue, 12 Feb 2008 16:27:15 -0700 X-Message-Number: 8526 Formatted message: HTML-formatted message In fulfilment of my action item from SMC-3 Working Group 14Jan08-01 Kevin Butt report to Geoff when IBM libraries set NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED sense code IBM sends Unit Attention, NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED (i.e., 6/2800h), under the following conditions: When a cartridge's logical library assignment changes (via user assignment or cartridge export ) When a user assigns a new volser to a cartridge (typically when the volser is blank or unreadable) When the library does a move that does not originate at the host (local move from UI) all Not Ready to Ready transitions (e.g., power-on reset, library control system reset, door closure, data transfer device reset when that DTD is being used as the SCSI port (e.g, DTD LUN 1 is being used as ADC local SMC device server)) Thanks, Kevin D. Butt SCSI & Fibre Channel Architect, Tape Firmware MS 6TYA, 9000 S. Rita Rd., Tucson, AZ 85744 Tel: 520-799-2869 / 520-799-5280 Fax: 520-799-2723 (T/L:321) Email address: kdbutt@us.ibm.com http://www-03.ibm.com/servers/storage/