To: roweber@IEEE.org, Black_David@emc.com, <matt.ball@IEEE.org> Cc: t10@t10.org Subject: DS_SAI length conflict between 07-437r4 and 07-169 & SPC-4 From: Kevin D Butt <kdbutt@us.ibm.com> Date: Fri, 21 Dec 2007 09:24:10 -0700 X-Message-Number: 8338 Formatted message: HTML-formatted message Ralph, David, and Matt, All the DS_SAI values in the ESP-SCSI (07-169r5) (e.g., Table x3 ? ESP-SCSI data-out buffer parameter list descriptor without initialization vector) are shown as 4-byte values as they are in SPC-4 Table 44 ? Minimum SA parameters. However 07-437r4 shows them as 8-byte values. I think 07-437r4 is correct and SPC-4 and 07-169 need to be modified to match. Thanks, Kevin D. Butt SCSI & Fibre Channel Architect, Tape Firmware MS 6TYA, 9000 S. Rita Rd., Tucson, AZ 85744 Tel: 520-799-2869 / 520-799-5280 Fax: 520-799-2723 (T/L:321) Email address: kdbutt@us.ibm.com http://www-03.ibm.com/servers/storage/