Robert,
Regarding
the proposal 07-297r1 , Table A.6 - CJTPAT with fixed content - is incorrect.
The columns "desired pattern" and "scrambled pattern" should be interchanged for rows 1 to 6. The "desired pattern" column represents what should be on the wire, while the "scrambled pattern" column represents what the application/transport layer sees. Obviously the newly added SSP header should be visible at the application/transport layer not on the wire.
Also, as a result, the CRC values in row 118 will be completely different.
Thanks
Tamer Kafafi
Senior Product Design Engineer, ESD
PMC-Sierra