Agenda:
1. StatEye simulations status:
Harvey, Kevin, Mike
SAS-2 Channel StatEye Simulation Results
(07-253) [Witt]
http://www.t10.org/ftp/t10/document.07/07-253r0.pdf
2. SAS-2:
Improving a Jitter Definition (07-205)
http://www.t10.org/ftp/t10/document.07/07-205r0.pdf
Feedback is needed from other measurement
equipment suppliers regarding the comments below.
Comments from Bent Hessen-Schmidt, SyntheSys
Research, Inc.:
I suggest that we use text equivalent to:
The Reference Clock characteristics are controlled
by the resulting JTF (Jitter Transfer Function) characteristics obtained
by taking the time difference between the PLL output (the Reference Clock)
and the data stream sourced to the PLL. The PLL CLTF -3 dB corner frequency,
and other adjustable CLTF parameters such a peaking, are determined by
the value required to meet the requirements of the JTF.
The JTF shall have the following characteristics
for an encoded D24.3 pattern (1100110011 0011001100). This is the MFTP
which is a test pattern that has clock-like characteristics and a transition
density of 0.5.
1) The -3 dB corner frequency of the JTF
shall be 3 MHz +/-1 MHz.
2) The magnitude peaking of the JTF shall
be 3.5 dB maximum.
3) The attenuation at 30 KHz +/-1% shall
be 75 dB +/-3 dB.
The JTF -3dB corner frequency and the magnitude
peaking requirements shall be measured with sinusoidal PJ applied, with
a peak-to-peak amplitude of 0.3 UI +/-10%. The relative attenuation at
30 KHz shall be measured with sinusoidal phase (time) modulation applied,
with a peak-to-peak amplitude of 20.8 ns +/-10%.
You will see that we have changed to from
72 db to 75 dB and from 2.1 MHz to 3 MHz and added the word “relative”
to the last sentence. Relative should indicate that the 75 dB are with
respect to the actual magnitude of jitter on the 30 kHz stimulus. The +/-10%
therefore merely sets the starting point and still allows the other vendor.
All uncertainties are then included in the +/-3 dB term. Effective tightening
of the tolerances can be seen on the residual of the 30 kHz being confined
to less than 5.2 ps instead of (7.4 x 1.1 x 1.1 ps = 8.95 ps).
3. 10-meter cable specification
(06-499r2)
Time domain versus frequency domain concerns.
4. Zero-length test load (07-013)
Update?
5. Additional
items and updates.
Alvin Cox
Seagate Technology, LLC
Office 405-381-8067
Cell 405-206-4809