I have found no reference to DC in the
existing specification of impedance values. The original SAS work included
the following with regards to impedance measurement:
All impedance measurements shall be TDR measurements
except where the receiver termination being tested includes inductive components
such as transformers. When inductive components exist in the receiver
termination, a swept frequency Return Loss or VSWR measurement may be more
appropriate. The frequency sweep shall cover the range Bit rate/10
to Bit rate/2.
As far as I can tell from the SAS perspective,
the term DC is first used in Kevin's proposal. It may have resulted from
the issue that we have not specifically stated how the measurements are
to be made (an item that Kevin Witt has indicated that we need in the SAS-2
specification) or it may be a carry-over from another specification (non-SAS).
Appendix B is very general in its measurement descriptions.
Alvin Cox
Seagate Technology, LLC
Tel 405-350-7424
Cell 405-206-4809
E-Mail alvin.cox@seagate.com