Subject: RE: SPC-4: Persistent Reserve Out Confusion Date: Thu, 8 Jun 2006 13:19:46 -0500 From: "Elliott, Robert (Server Storage)" <Elliott@hp.com> To: <t10@t10.org> X-Message-Number: 6945 Attachment #1: smime.p7s SPEC_I_PT used to work with REGISTER AND IGNORE EXISTING KEY, but that combination was removed by the REGISTER AND MOVE service action proposal 03-337 (apparently incompletely). SPC-3 letter ballot comments to reinstate it were rejected, saying a detailed proposal would be needed to make such a change in SPC-4. -- Rob Elliott, elliott@hp.com Hewlett-Packard Industry Standard Server Storage Advanced Technology https://ecardfile.com/id/RobElliott > -----Original Message----- > From: owner-t10@t10.org [mailto:owner-t10@t10.org] On Behalf > Of Hubis, Walt > Sent: Thursday, June 08, 2006 11:44 AM > To: t10@t10.org > Subject: SPC-4: Persistent Reserve Out Confusion > > * From the T10 Reflector (t10@t10.org), posted by: > * "Hubis, Walt" <Walt.Hubis@lsil.com> > * > In SPC4-04, Section 5.6.6 "Registering", Table 34 "Register behaviors > for a REGISTER AND IGNORE EXISTING KEY service action", anytime the > SERVICE ACTION RESERVATION KEY is non-zero and SPEC_I_PT is > set to one, > a CHECK CONDITION status is to be generated. But in section 6.12.3 > "Basic PERSISTENT RESERVE OUT parameter list" states: > > "If the SPEC_I_PT bit is set to one for the REGISTER service action or > the REGISTER AND IGNORE EXISTING KEY service action, then the > additional > parameter data shall include a list of transport IDs (see > table 116) and > the device server shall also apply the registration to the > I_T nexus for > each initiator port specified by a TransportID. If a > registration fails > for any initiator port(e.g., if the logical unit does not have enough > resources available to hold the registration information), none of the > other registrations shall be made." > > This seems to be a contradiction - what am I missing here? > > Cheers, > Walt > > --- > > Walt Hubis walt.hubis@lsil.com <mailto:walt.hubis@lsil.com> > Software Architect > Engenio Storage Group > > LSI Logic Corporation > 5400 Airport Blvd Ste 100 > Boulder, Colorado 80301 USA > Phone: (303) 381-4332 > www.lsilogic.com/engenio > > > > * > * For T10 Reflector information, send a message with > * 'info t10' (no quotes) in the message body to majordomo@t10.org >